0.25" Armor with 0.028" wall, 316L

Application

Armored cable for artificial lift downhole monitoring systems.

0.25 TEC Cable
Features
  • 18 AWG Copper conductor
  • 150°C Rated Blue Polyolefin Filler
  • 316L Stainless Steel
    Dimensional Specifications
     Value (in)Tolerance (in)
    Conductor Diameter0.0460+ 1 %, - 5%
    Insulated Diameter0.0980± 0.002
    Insulation Wall0.0260± 0.002
    Filler Diameter0.194
    Filler Wall0.048
    Filler Concentricity80
    Armor Diameter0.250± 0.002
    Armor Thickness0.028+ 0.0005, - 0.0025
    Roundness0.0010.002 max
    Encapsulation Min. Axis0.433± 0.024
    Encapsulation Max. Axis± 0.024± 0.024


    Dimensional Specifications
     ValueTolerance
    Armor Tensile Strength (psi)135,000± 35,000
    Armor Yield Strength (psi)125,000± 35,000
    Armor Elongation15%± 10%
    Tube Hardness (HRc)3035 max
    Cable Collapse Pressure (psi)17,500± 5,000
    Cable Working Pressure (psi)13,125
    Core Pullout Force (lbf)105 min, 55 max
    Filler Stripping Force (lbf)2010 min, 30 max
    Cable Weight (lb/1000’)146± 15
    Service Temperature Range100°C-25°C to 150°C


    Electrical Specifications
     TemperatureValueTolerance
    Conductor Resistance (?/1000’)20°C77 (max)
    150°C1111 (max)
    Armor Resistance (?/1000’)20°C18.5± 2.0
    150°C19.1± 2.0
    Capacitance (pF/ft)20°C29.9 max
    150°C27.5
    Insulation Resistance (M?-1000’)6,500 min
    Velocity of Propagation (%Vel. Light)
    Cutoff Frequency (MHz)72.2± 0.2
    Effective Impedance (?)22,425± 1,500
    Effective Inductance (uH/ft)0.08± 0.01
    Voltage Rating 3kV 5 min1,000 V
    0.25 TEC Cable