0.25 TEC Cable
0.25 TEC Cable
0.25" Armor with 0.028" wall, 316L
Application
Armored cable for artificial lift downhole monitoring systems.
Features
- 18 AWG Copper conductor
- 150°C Rated Blue Polyolefin Filler
- 316L Stainless Steel
| Dimensional Specifications | ||
|---|---|---|
| Value (in) | Tolerance (in) | |
| Conductor Diameter | 0.0460 | + 1 %, - 5% |
| Insulated Diameter | 0.0980 | ± 0.002 |
| Insulation Wall | 0.0260 | ± 0.002 |
| Filler Diameter | 0.194 | |
| Filler Wall | 0.048 | |
| Filler Concentricity | 80 | |
| Armor Diameter | 0.250 | ± 0.002 |
| Armor Thickness | 0.028 | + 0.0005, - 0.0025 |
| Roundness | 0.001 | 0.002 max |
| Encapsulation Min. Axis | 0.433 | ± 0.024 |
| Encapsulation Max. Axis | ± 0.024 | ± 0.024 |
| Dimensional Specifications | ||
|---|---|---|
| Value | Tolerance | |
| Armor Tensile Strength (psi) | 135,000 | ± 35,000 |
| Armor Yield Strength (psi) | 125,000 | ± 35,000 |
| Armor Elongation | 15% | ± 10% |
| Tube Hardness (HRc) | 30 | 35 max |
| Cable Collapse Pressure (psi) | 17,500 | ± 5,000 |
| Cable Working Pressure (psi) | 13,125 | |
| Core Pullout Force (lbf) | 10 | 5 min, 55 max |
| Filler Stripping Force (lbf) | 20 | 10 min, 30 max |
| Cable Weight (lb/1000’) | 146 | ± 15 |
| Service Temperature Range | 100°C | -25°C to 150°C |
| Electrical Specifications | |||
|---|---|---|---|
| Temperature | Value | Tolerance | |
| Conductor Resistance (?/1000’) | 20°C | 7 | 7 (max) |
| 150°C | 11 | 11 (max) | |
| Armor Resistance (?/1000’) | 20°C | 18.5 | ± 2.0 |
| 150°C | 19.1 | ± 2.0 | |
| Capacitance (pF/ft) | 20°C | 29.9 max | |
| 150°C | 27.5 | ||
| Insulation Resistance (M?-1000’) | 6,500 min | ||
| Velocity of Propagation (%Vel. Light) | |||
| Cutoff Frequency (MHz) | 72.2 | ± 0.2 | |
| Effective Impedance (?) | 22,425 | ± 1,500 | |
| Effective Inductance (uH/ft) | 0.08 | ± 0.01 | |